Sphase US Series Electrostatic Filter Systems. Technical Data has been added visually. You can add options according to your needs. You can use the calculation table below to select capacity. If you have any doubts about the choice, you can contact us. Capacity Determination: When you multiply the width and length of your hood in metres, the result is 3,000 m3/h if it is less than '1.3', then 6,000 m3/h if it is less than '2.4', then 9,000 m3/h if it is less than '3.6'. If it is smaller than 8', a capacity of 12,000 m3/h is sufficient. Example; A 3,000 m3/h Filter system is suitable for hood length 1.7 meters, hood width 0.7 meters 1.7x0.7= 1.19m2. Note: This calculation method is valid for wall-mounted hoods. Request technical support for the calculation of island type hoods. If you are not sure about the result, you can contact us. Stage Selection: Electrostatic filters are used gradually according to the density of smoke and oil vapor. The 'Dual Stage' option includes two 12,000 m3/h electrostatic filters, and the Three stage option includes three 12,000 m3/h electrostatic filters. Single Stage; In kitchens where the smoke density is very low, such as Doner Restaurant, Sulu Meal, Patisserie, Frying House and General Kitchen. Double Stage ; In kitchens with medium smoke emissions such as Gas or Electric Grills and Fryers. Three Stages; In all kitchens with a charcoal grill. (99.7% smoke filtration is guaranteed.)Active Carbon Filter; In addition to filtering smoke and oil, Electrostatic Filters also reduce odor by 50%. In places where this ratio is not sufficient, an active carbon filter should be used. The active carbon filter used after the Electrostatic Filter provides odor filtration reaching 87% efficiency. Panel Cassette Type; It is used in places where odor intensity is low. It contains less granulated carbon than the cylinder cartridge type. The replacement cost is lower. The change period is between 6 months and 1 year. Cylinder Cartridge Type; It is used in places where odor intensity is high. Contains 64 pieces of 400mm length cylinder activated carbon cartridges for a capacity of 3,000 m3/h. The change period is between 6 months and 1 year. Aspirator Unit; An aspirator unit is used so that the dirty air collected in the hood can pass through the filter and be discharged to the outside environment. If you already have an aspirator system, you can use it in your filter system, provided that it is suitable. You do not need to purchase this option. You can contact us to decide on eligibility. Duct Fan; It is used in hoods that do not exceed 2 square meters, in places where the duct system does not exceed 8 meters, and in systems that do not contain active carbon. It is low cost and quiet. Cell Aspirator; It is used in hoods over 2 square meters, in systems containing active carbon filters and in places where the duct length exceeds 8 meters. Thanks to its insulated cell structure, it is silent and vibration-free. It is long lasting and durable. UVC Ozone Filter; It is used as an alternative to Active Carbon Filter in places where odor density is low. It eliminates bad odors by disrupting the structure of odor molecules with the ozone gas it releases. The change period is approximately 1.5 years. Thanks to its low pressure loss, it can be used with the 'Duct Fan'. Input / Output Reduction ; It is the adapter part required to connect the dirty air inlet and clean air outlet section to the round duct. When you purchase this option, you can attach the pipes directly to the filter without needing any other parts.